Rabu, 06 April 2016

IKA Colorimeter C 2000 basic version 1

IKA Colorimeter C 2000 basic version 1


Description 

The C 2000 basic IKA- calorimeter is a combustion calorimeter for determining gross calorific values of liquid and solid samples. A high level of automation with extremely simple handling characterizes this instrument. In addition to the isoperibolic measurement procedure (static jacket), a dynamic (reduced-time) working method is also available. To provide the calorimeter with cooling water, it needs to be connected to a thermostat f.e. IKA KV 600 ( accessory) or a firmly installed water connection. The C 2000 basic is equipped with a very convenient console to operate the unit. 
- Automatic water handling system includes tempering, filling and emptying of calorimeter inner vessel 
- Automatic oxygen filling of decomposition vessel 
- Automatic decomposition vessel identification 
- Automatic sample ignition 
- Validation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711 
- Working methods: isoperibol, measurement time: approx. 22 min / dynamic, measurement time: approx. 7 min 
- Compact, integrated modular design for convenient operation 
- Cooling water supply via thermostat f.e. IKA KV 600 (accessory) or firmly installed water connection (C 25 pressure regulating valve recommended) 
- Interface connections for each of the following: scale, printer, monitor and sample rack C 5020 
- User-friendly software C 5040 CalWin for controling the calorimeter and administration of measuring data 
- Up to eight measurement cells can be controlled by a single PC, using a multi-serial plug-in card PCI 8.2 (accessory) 
- LIMS integration is possible 
- Special halogen resistent vessel for quantitative decomposition of halogens and sulfur ( accessory) 
- The decomposition vessel can be changed over to use combustible crucibles C 14 ( accessory C5010.4 is needed) 
- Consumables for calibrations and initial operation are included with delivery. 


Technical Data 

Measuring range max.40000 J
Measuring mode adiabatic 22°Cno
Measuring mode isoperibol 22°Cno
Measuring mode dynamic 25°Cyes
Measuring mode isoperibol 25°Cyes
Measuring mode dynamic 30°Cyes
Measuring mode isoperibol 30°Cyes
Measuring mode double dry (ISO 1928)no
Measuring time dynamic approx.7 min
Measuring time isoperibol approx.22 min
Reproducibility dynamic (1g benzoic acid NBS39i)0.1 %RSD
Reproducibility isoperibol (1g benzoic acid NBS39i)0.05 %RSD
Working temperature max.30 °C
Temperature measurement resolution0.0001 K
Cooling medium temperature min.12 °C
Cooling medium temperature max.28 °C
Cooling medium permissible operating pressure1.5 bar
Cooling mediumtap water
Type of coolingflow
Flow rate min.60 l/h
Flow rate max.70 l/h
Oxygen operating pressure max.40 bar
Interface scaleRS232
Interface printerCentronix
Interface PCRS232
Interface test rackyes
Interface ext. monitoryes
Interface ext. keyboardyes
Oxygen fillingyes
Degasificationno
Decomposition detectionyes
Decomposition vessel C 5010yes
Decomposition vessel C 5012no
Decomposition vessel C 7010no
Decomposition vessel C 7012no
Decomposition vessel C 62no
Analysis according to DIN 51900yes
Analysis according to ASTM D240yes
Analysis according to ASTM D4809yes
Analysis according to ASTM D1989yes
Analysis according to ASTM D5468yes
Analysis according to ASTM D5865yes
Analysis according to ASTM E711yes
Dimensions (W x H x D)440 x 500 x 450 mm
Weight35 kg
Permissible ambient temperature20 - 25 °C
Permissible relative humidity80 %
Protection class according to DIN EN 60529IP 21
RS 232 interfaceyes
Voltage220 - 240 / 100 - 120 V
Frequency50/60 Hz
Power input1800 W

Tidak ada komentar:

Posting Komentar