OHAUS STARTER 2100

OHAUS STARTER 2100
Economical pH Bench Meter for Basic Laboratory Applications
After more than a century of perfecting the art of measurement through our durable weighing products, OHAUS precision is now available in a line of benchtop pH meters. Starter 2100 is the economical choice for applications requiring simple pH measurement.
  • The built-in electrode holder provides uncomplicated and convenient all-in-one operation while the large LCD display screen clearly displays results.
  • Auto buffer recognition, electrode condition icon, automatic temperature compensation and reference input all work to ensure accurate results.
  • With the attached quick guide, five clearly marked keys and user friendly software, novices can operate the meter with minimal training.


Models 
  • pH
  • oxidation-reduction potential (ORP) measurement

FEATURES 
TYPEDESCRIPTIONPICTURE
DisplayLiquid crystal display (LCD)
OperationAC adapter (included)
ConstructionABS housing, built-in electrode holder
Design FeaturesAuto buffer recognition, two point calibration, quick reference guide

OHAUS STARTER 3100C

OHAUS STARTER 3100C
Smart Conductivity Bench Meter for Standard Laboratory Applications

0.5%FS, 99 sets memory, RS232 with stand alone electrode holder
  • Starter 3100C's intuitive software includes four calibration points, automatic and manual endpoint functions, and one touch conversion between measurement modes.
  • Among Starter 3100C's user-friendly features that support ease-of-use are an adjustable standalone electrode holder and large backlit LCD display.
  • Documenting measurement data is made simple through the RS232 which can be used to connect peripheral devices such as printers or computers to the meter.


  • APPLICATION 

  • Conductivity
  • total dissolved solids (TDS)
  • salinity measurement

    FEATURES 
TYPEDESCRIPTIONPICTURE
DisplayBacklit liquid crystal display (LCD)
OperationAC adapter (included)
ConstructionABS housing, standalone electrode holder, replaceable in-use cover

OHAUS STARTER 5000

STARTER 5000
High Performance Bench Meter for Universal pH Applications
Backed by OHAUS’ century-old commitment to providing precise measurement, Starter 5000 provides accurate pH and ORP measurement for high-level experiments and research. Enhanced features, advanced technology, and high performance have been combined to support complex laboratory tasks requiring pH measurement.
  • Starter 5000's performance is propelled by a 1000 item library, 10 sensors for calibration storage, 8 predefined and 1 self-defined buffer groups, 3 endpoint modes and GLP mode.
  • The color touchscreen operates similar to smartphones and tablet computers and provides simple operation of the advanced features, such as one-touch toggling of measurement modes.
  • With a standalone electrode holder, USB port, IP54 housing and in-use-cover, Starter 5000 provides the flexibility and protection that ensures smooth and enduring operation.\


Minggu, 28 Februari 2016

HIOKI WIRELESS CLAMP LOGGER LR8513 Measure Load Current and Leak Current Easily with Clamp Sensors


WIRELESS CLAMP LOGGER

LR8513

Measure Load Current and Leak Current Easily with Clamp Sensors


Hioki Memory HiLoggers are high-speed data loggers for recording multiple channels of voltage, temperature, resistance or humidity signals, some models providing complete isolation between channels and strong noise resistance. The Hioki LR8513 is a wireless, 2-channel AC/DC current input module that utilizes Bluetooth® technology to either send measured data to the Hioki LR8410 Wireless Logging Station or to an Android (TM) tablet.

Key Features

• Measure AC and DC load current and AC leak current • Choose from eight current sensors • Place inside a distribution panel, close the cover, and monitor measured values from the outside • Measure power easily—just set the voltage and power factor • Compact, two-channel model fits where other devices don’t • Measurement data is sent to the Hioki LR8410-20 using Bluetooth® wireless technology • Measurement data is saved even when communications are interrupted • Three-way power (AC adapter, AA alkaline batteries, or external 5 to 13.5 V power supply) • Instrument can store 500,000 data points per channel

■ Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Supported instrument[Used as standalone product (Data collected manually) ]
Windows PC or Windows tablet (CD-R with software included)
Android smartphone or Android tablet terminal
(Software can be downloaded free of charge from Google Play.)
*Communication range varies with the performance of the computer or tablet (up to a line-of-sight distance of roughly 30 m)
[Used as logging module (Real-time measurement) ]
Device can be used as an LR8410 logging module to record and display data in real time and to control up to 7 units, Communication distance: 30 m
Number of channels2ch (common GND)
Measurement itemsAC load current, DC load current, AC leak current (using current sensor)
Effective value calculationSoftware calculates the true RMS value
Measurement range500.0 mA to 2000 A AC, 10.00 A to 2000 A DC (By current sensor)
*Current and leak current that occur intermittently cannot be measured.
Measurement Accuracy±0.5% rdg.±5 dgt. (DC, AC 50/60 Hz) *Add the sensor’s accuracy when the current sensor is connected
Display itemsMeasurement value, date, time, number of recorded data, maximum value, minimum value, and average value
FunctionsAlarm, Scaling, Recording operation hold function, Erroneous operation prevention, Comment recording function, Power saving function, Authentication function, Free run
Recording[Capacity] 500,000 data items for each channel [Mode] Instantaneous value, average value, maximum value [Interval] 0.5 to 30 sec, 1 to 60 min, 14 selections
Power sourceAC Adapter Z2003 (100 to 240 V AC, 50/60 Hz), AA alkaline batteries (LR6) ×2, External power 5 to 13.5 V DC (can also be supplied from USB bus power, with a conversion cable)
Continuous operating time ([Capacity] 500,000 data items for each channel) (23˚C)3 months (Recording interval of 1 min, Bluetooth® OFF), 10 days (Recording interval of 1 sec, Bluetooth® ON), 5 days (Recording interval of 0.5 sec, during real-time measurement with the LR8410)
Dimensions and mass85 mm (3.35 in) W × 75 mm (2.95 in) H × 38 mm (1.50 in) D, 130 g (4.6 oz) (excluding the battery)
AccessoriesCD-R ×1 (Instruction Manual, Logger Utility, Wireless Logger Collector), Measurement Guide ×1, Caution for Using Radio Waves × 1, AA alkaline batteries (LR6) ×2

HIOKI WIRELESS HUMIDITY LOGGER LR8514 Temperature and Humidity Data Logger for Managing Production Plants and Agricultural Sites


WIRELESS HUMIDITY LOGGER

LR8514

Temperature and Humidity Data Logger for Managing Production Plants and Agricultural Sites


Hioki Memory HiLoggers are high-speed data loggers for recording multiple channels of voltage, temperature, resistance or humidity signals, some models providing complete isolation between channels and strong noise resistance. The Hioki LR8514 Wireless Humidity Logger provides easy, wireless collection of temperature and humidity data, and is the ideal tool for managing the environmental condition of production plants and agricultural sites.

Key Features

• High-precision, ±3% RH humidity sensor • Convenient for simultaneously recording and comparing temperature and humidity readings at 2 locations • Compact, two-channel model fits where other devices don’t • Download measurement data to a tablet or computer with Bluetooth® wireless technology or capture in real time with the LR8410 • Three-way power (AC adapter, AA alkaline batteries, or external 5 to 13.5 V power supply) • Store 500,000 data points per channel

■ Basic specifications

Supported instrument[Used as standalone product (Data collected manually) ]
Windows PC or Windows tablet (CD-R with software included)
Android smartphone or Android tablet terminal
(Software can be downloaded free of charge from Google Play.)
*Communication range varies with the performance of the computer or tablet (up to a line-of-sight distance of roughly 30 m)
[Used as logging module (Real-time measurement) ]
Device can be used as an LR8410 logging module to record and display data in real time and to control up to 7 units, Communication distance: 30 m
Number of channels2 ch for temperature + 2 ch for humidity (2 sensors can be attached)
Measurement itemsTemperature, Humidity
Measurable Range[Temperature] -40 ˚C to 80 ˚C, Range 100˚C f.s., Max. resolution 0.1˚C
[Humidity] 0 to 100% RH, Range 100% RH f.s., Max. resolution 0.1%RH
Measurement accuracy (using Z2010/ Z2011)[Temperature basic accuracy] ±0.5 ˚C (10 to 60 ˚C)
*If outside above temperature range: Add 0.015 ˚C/ ˚C (-40 to 10 ˚C) or 0.02˚ C/ ˚C (60 to 80 ˚C)
[Humidity basic accuracy] ±3% RH (20 to 30 ˚C, 20 to 90% RH)
Display itemsMeasurement value, date, time, number of recorded data, maximum value, minimum value, and average value
FunctionsAlarm, Scaling, Recording operation hold function, Erroneous operation prevention, Comment recording function, Power saving function, Authentication function, Free run
Recording[Capacity] 500,000 data items for each channel [Mode] Instantaneous value [Interval] 0.5 to 30 sec, 1 to 60 min, 14 selections
Power sourceAC Adapter Z2003 (100 to 240 V AC, 50/60 Hz), AA alkaline batteries (LR6) ×2, External power 5 to 13.5 V DC (can also be supplied from USB bus power, with a conversion cable)
Continuous operating time ([Capacity] 500,000 data items for each channel) (23˚C)3.5 months (Recording interval of 1 min, Bluetooth® OFF), 20 days (Recording interval of 1 sec, Bluetooth® ON), 5 days (Recording interval of 0.5 sec, during real-time measurement with the LR8410)
Dimensions and mass85 mm (3.35 in) W × 61 mm (2.40 in) H × 31 mm (1.22 in) D (Excluding protrusions), 95 g (3.4 oz) (Not including the battery)
AccessoriesCD-R ×1 (Instruction Manual, Logger Utility, Wireless Logger Collector), Measurement Guide ×1, Caution for Using Radio Waves ×1, AA alkaline batteries (LR6) ×2

HIOKI WIRELESS FUNGAL LOGGER LR8520 Data Logger to Prevent Fungal Occurrence in Business Critical Locations



WIRELESS FUNGAL LOGGER

LR8520

Data Logger to Prevent Fungal Occurrence in Business Critical Locations


Hioki Memory HiLoggers are high-speed data loggers for recording multiple channels of voltage, temperature, resistance or humidity signals, some models providing complete isolation between channels and strong noise resistance. The Hioki LR8520 is a wireless and compact 1ch logger that records fungal index and growth prediction to easily prevent fungal growth. The logger utilizes Bluetooth® technology to either send measured data to the Hioki LR8410 Wireless Logging Station or to an Android (TM) tablet.

Key Features

• High-precision ±3% rh humidity sensors • Calculate and diaplay fungal index*1 and growth prediction • Measure temperature and humidity other than fungal index and growth prediction • Compact 1ch logger (Temperature/Humidity each 1 ch input) • Download measurement data to a tablet or computer with Bluetooth® wireless technology or capture in real time with the LR8410 • Three-way power supplys (AC adapter, AA alkaline batteries, or external 5 to 13.5 V power supply) • Store 500,000 data points per channel

■ Basic specifications

Supported instrument[Used as standalone product (Data collected manually) ]
Windows PC or Windows tablet (CD-R with software included)
Android smartphone or Android tablet terminal
(Download app from Google Play)
*Communication range varies with the performance of the computer or tablet
(up to a line-of-sight distance of roughly 30 m)
[Used as unit (Real-time measurement) ]
Device can be used as an LR8410 logging module to record and display data in real time and to control up to 7 units, Communication distance: 30 m
Number of channels1 temperature channel + 1 humidity channel (Humidity sensor Z2010 or Z2011 is required (sold separately))
Display itemsTemperature, humidity, fungal index (0 to 200), growth prediction (5 levels)
Measurable range[Temperature] -40˚C to 80˚C, Range 100˚C f.s., Max. resolution 0.1˚C
[Humidity] 0% to 100% RH, Range 100% RH f.s., Max. resolution 0.1% RH
Measurement accuracy (using Z2010/Z2011)[Temperature] ±0.5 ˚C (10˚C to 60˚C), If outside above temperature range: Add 0.015 ˚C/ ˚C (-40 ˚C to 10 ˚C) or 0.02˚ C/ ˚C (60 ˚C to 80 ˚C)
[Humidity] ±3% RH (20˚C to 30 ˚C, 20% to 90% RH)
Other functionsMeasurement value, Date, Time, Number of recorded data, Maximum value, Minimum value, Average value, Alarm, Scaling, Recording operation hold function, Erroneous operation prevention, Comment recording function, Power saving function, Authentication function
Recording[Capacity] 500,000 data items for each channel [Mode] Instantaneous value [Interval] 0.5 sec to 30 sec, 1 min to 60 min, 14 selections
Power supplyACAdapter Z2003 (100 to 240 V AC, 50 /60 Hz), AA alkaline batteries (LR6) × 2, External power 5 to 13.5 V DC (can also be supplied from USB bus power via a conversion cable)
Continuous operating time ([Capacity] 500,000 data items for each channel) (23˚C)3.5 months (Recording interval of 1 min, Bluetooth® OFF), 20 days (Recording interval of 1 sec, Bluetooth® ON), 5 days (Recording interval of 0.5 sec, during real-time measurement with the LR8410)
Dimensions and mass85 mm (3.35 in) W × 61 mm (2.40 in) H × 31 mm (1.22 in) D (Excluding protrusions), 95 g (3.3 oz) (Not including the battery)
AccessoriesCD-R (Instruction Manual, Logger Utility, Wireless Logger Collector) ×1, Measurement Guide ×1, Caution for Using Radio Waves ×1, AA alkaline batteries (LR6) ×2 , Connection cable L1010 ×1

HIOKI MEMORY HiCORDER 8860-50, 8861-50


MEMORY HiCORDER

8860-50, 8861-50

High-speed 16- or 32-channel Memory Recorders Offer Data Acquisition, Oscilloscope and Data Logger Functionality to Record Waveforms in Any Situation


Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple physical phenomena such as voltage, current, temperature, vibration, weight, acceleration and rotation due to complete isolation between channels and from each channel to the ground. More than just a digital oscilloscope, the 8860-50 and 8861-50 memory recorders accommodate plug-and-play input modules to meet applications such as monitoring commercial power supplies, fault analysis of electrical equipment, evaluating electric vehicle chargers, and analyzing conveyor belt speeds.

Key Features

•A faster CPU greatly enhances instrument operability and response. •Multi-channel logging on up to 64 or 128 channels (with 8958 Scanner Unit) •20 MS/s high-speed sampling and data acquisition (DAQ) (with 8956 Analog Unit) •LAN/USB/PC-card slot built-in •High-voltage input module for measuring high voltage directly

■ Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

8860-508861-50
Number of input unitsMax. 4 unitsMax. 8 units
Number of channelsMax. 16 analog channels (Max. 64 channels when using the 8958) + standard 16 logic channelsMax. 32 analog channels (Max. 128 channels when using the 8958) + standard 16 logic channels
Measurement ranges (20 div full-scale)5 mV to 20 V/div, 12 ranges (when using the 8956), Resolution : 1/100 of range5 mV to 20 V/div, 12 ranges (when using the 8956), Resolution : 1/100 of range
Max. allowable inputDC 400V (when using the 8956)DC 400V (when using the 8956)
Frequency characteristicsDC to 10 MHz (-3dB, when using the 8956)DC to 10 MHz (-3dB, when using the 8956)
Time axis at memory function5 µs to 5 min/div, 26 ranges, sampling period : 1/100 of range, external sampling, dual timebase possible
Measurement functionsMEM (high-speed recording) REC (real-time recording) REC & MEM (realtime recording + high-speed recording) FFT (frequency analysis) Real-time Save (records directly to storage media)
Storage memory capacity12-bits × 32M-words/ch (1ch at 8860-50, 2ch at 8861-50) to 2M-words/ch (16ch at 8860-50, 32ch at 8861-50)
*Memory capacity can be expanded 32 times. (Optional memory board)
Removable storageUSB 2.0 memory × 3, PC card Type II slot × 2, Hard disk drive (option) × 1
Recording paper[Built in optional printer unit] A4: 216 mm (8.50 in) × 30 m (98.43 ft), or A6: 112 mm (4.41 in) × 18 m (59.06 ft) selectable, thermal paper roll, Recording speed : Max. 25 mm (0.98 in)/sec
Display10.4-inch SVGA-TFT color LCD (800 × 600 dots)
External interfacesUSB 2.0, LAN, Monitor output (15 pin D-sub output), *GP-IB is Not Available
Power supply100 to 240 V AC (50/60 Hz) (220 VA max. printer not used)
12 V DC (use the DC power unit 9684 : option, factory installation only)
100 to 240 V AC (50/60 Hz) (280 VA max. printer not used)
12 V DC (use the DC power unit 9684 : option, factory installation only)
Dimensions and mass330 mm (12.99 in) W × 250 mm (9.84 in) H × 184.5 mm (7.26 in) D, 8 kg (282.2 oz) (printer not installed)330 mm (12.99 in) W × 250 mm (9.84 in) H × 284.5 mm (11.20 in) D, 10.5 kg (370.4 oz) (printer not installed)
AccessoriesQuick Start Manual × 1, Input Module Guide × 1, Instruction Manual × 1, Analysis and Communication Supplement × 1, Application Disk (WaveViewer Wv, communication commands table) × 1, Power cord × 1, Input cord label × 1, Ferrite clamp (for LAN cable) × 1