AC Digital Clamp MetersAC Analogue Clamp Meters
AC/DC Digital Clamp MetersFork Current Tester
Leakage Clamp Meters


DC Milliamp Clamp Meter

KEW2500
 
Selection GuideProduct CatalogueInstruction Manual
 
2500
0.01mA resolution for DC current
Top class measurement 0.2% accuracy
Φ6mm clamp jaw easy to use in tight places
Measurement from 0.01mA to 120.0mA
Dual display with backlight shows both mA measurement and percent of 4-20 mA span
Spotlight for illuminating measurement point
Analog output terminal for recorder connection
Complies with IEC 61010-1 CAT II 300V



PageTop
AC Digital Clamp Meters

MODEL2117R
 
Selection GuideProduct CatalogueInstruction Manual
 
2117R
NEW
Fully Safety jaw
Ergonomic over-molded body gives convenient one-hand operation
Large easy-to-read display with 0.01A resolution
Accurate reading with True RMS
60/600/1000A auto-ranging
Long battery life
Safety Standard
IEC 61010-1 CAT IV 300V / CAT III 600V

MODEL2200R
 
Selection GuideProduct CatalogueInstruction Manual
 
2200R
NEW
Ultra slim and lightweight Handy design
Φ33mm Tear Drop Jaw easy to use in tight places
1000A AC Clamp Meter
DMM function ACV, DCV, &Ohm, Continuity Buzzer
Fuseless electronic protection on Ω/ up to 600V
Safety Standard
IEC 61010-1, 61010-2-032 CAT IV 300V / CAT III 600V

MODEL2210R
 
Selection GuideProduct CatalogueInstruction Manual
 
2210R
NEW
Flexible and light weight clamp sensor
Wide reading range up to 3000A
True RMS
MIN MAX function
Backlight LCD display
IEC 61010-1 (CAT III 1000V / CAT IV 600V)

MODEL2002PA
 
Selection GuideProduct CatalogueInstruction Manual
 
2002PA

Can measure large AC current up to 2000A.
Peak hold function.
55mm-dia large tear drop shaped jaws.

MODEL2002R
 
Selection GuideInstruction Manual
 
2002R

Can measure large AC current up to 2000A.
Peak hold function.
55mm-dia large tear drop shaped jaws.

MODEL2007A
 
Selection GuideProduct CatalogueInstruction Manual
 
2007A

Sleep function to save battery
Data hold function.
Digital display with maximum 4000 counts.

MODEL2017
 
Selection GuideInstruction Manual
 
2017
Tear drop shaped jaws for ease of use in tight places and crowded cable areas.
Designed to meet internationally proven safety standards such as
IEC 61010-1, UL3111 and VDE0411.
Three functions in one unit; AC current, AC voltage and resistance.
Resistance range provides audible continuity test.
Frequency response from 40Hz to 1kHz on AC current and voltage ranges.

MODEL2027
 
Selection GuideInstruction Manual
 
2027
True RMS reading instrument that permits precise measurements of nonsinusoidal waveform AC current and voltage. Accurate measurements are also possible at low frequencies from 10Hz upwards.
Designed to meet internationally proven safety standards such as
IEC 61010-1, UL3111 and VDE0411.
Three functions in one unit; AC current, AC voltage and resistance.

MODEL2031
 
Selection GuideProduct CatalogueInstruction Manual
 
2031

Can measure large AC current up to 200A.
24mm-dia tear drop shaped jaws.

KEW2040
Selection GuideProduct CatalogueInstruction Manual
 
2040
Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
Thus, very useful for power distribution companies, power utilities and maintenance fields.

KEW2200
 
Selection GuideProduct CatalogueInstruction Manual
 
2200
The Slim and Lightweight 1000A AC Clamp Meter



PageTop
AC Analogue Clamp Meters

MODEL2608A
 
Selection GuideProduct CatalogueInstruction Manual
 
2608A

DC voltage range is also available especially for checking emergency battery operated power supply.
Can measure temperature using optional probe.
Tear drop shaped transformer jaws for ease of use.

MODEL2805
 
Selection Guide
 
2805

Range switch selects only one rotary scale at a time, making it easy to take readings correctly.
A long time seller with proven reputation world wide for its easy-to-use functions.



PageTop
AC/DC Digital Clamp Meters

KEW2003A
 
Selection GuideProduct CatalogueInstruction Manual
 
2003A
Equipped to measure both AC and DC current with transformer jaws of large diameter.
Can measure AC and DC currents up to 2000A.
Output terminal for connection to recorders.

KEW2009R
 
Selection GuideProduct CatalogueInstruction Manual
 
2009R
CAT IV Clamp Meter can measure the Voltage and Current in both very low and high power circuits.
Accurate True-RMS reading of AC current or voltage with distorted waveform.
Can measure AC and DC currents up to 2000A.
Output terminal for connection to recorders.

MODEL2010
 
Selection GuideInstruction Manual
 
2010

High sensitivity, miniature AC/DC clamp meter.
0.1mA minimum resolution for AC current and 1mA minimum resolution for DC current.
Output terminal for recorder connection.

MODEL2033
 
Selection GuideProduct CatalogueInstruction Manual
 
2033

Smallest clamp meter capable of AC and DC current measurements.
300A auto ranging has minimum resolution of 0.01A AC/DC.
Auto-zero function to allow one touch zero adjustment.

KEW2046R
Selection GuideProduct CatalogueInstruction Manual
 
2046R
Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
Thus, very useful for power distribution companies, power utilities and maintenance fields.
True RMS enables an accurate measurement.

KEW2055
Selection GuideProduct CatalogueInstruction Manual
 
2055
Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
Thus, very useful for power distribution companies, power utilities and maintenance fields.

KEW2056R
Selection GuideProduct CatalogueInstruction Manual
 
2056R
Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
Thus, very useful for power distribution companies, power utilities and maintenance fields.
True RMS enables an accurate measurement.



PageTop
Fork Current Tester

MODEL2300R
 
Selection GuideProduct CatalogueInstruction Manual
 
2300R
True RMS reading is an essential feature for accurate measurement.
“Non Contact” voltage function indicates the presence of AC voltage by warning the user with an audible signal.
Set the DC current range to zero in one touch with the Zero Adjust function.



PageTop
Leakage Clamp Meters

MODEL2412
 
Selection GuideInstruction Manual
 
2412
Digital clamp meter with tear drop shaped, medium size transformer jaws specially designed for leakage current measurement.
Frequency filter switch to eliminate the effect of harmonics.
Output terminal for connection to recorders and facility to operate from external power supply permit continuous leakage current monitoring.

KEW2413F
 
Selection GuideInstruction Manual
 
2413F
Extra wide transformer jaws are best suited for clamping on all three or four wires (3phases) together for leakage current measurement.
Frequency filter switch to eliminate the effect of harmonics.
Output terminal.

KEW2413R
Leakage Clamp Meter
Selection GuideInstruction Manual
 

2413R

Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
True RMS enables an accurate measurement for distorted waveforms.
Measurement from mA up to AC 1000A
Frequency filter switch to eliminate the effect of the harmonics.
2 way analogue output terminal

MODEL2431
 
Selection GuideProduct CatalogueInstruction Manual
 
2431

Frequency Selector Switch to eliminate the effect of harmonics.
Three AC current ranges 20mA/200mA/200A.
Rotary switch for easy one finger power-on and range selection.

MODEL2432
 
Selection GuideProduct CatalogueInstruction Manual
 
2432

High Sensitive Model
Frequency Selector Switch to eliminate the effect of harmonics.
Three AC current ranges:4mA/40mA/100A

MODEL2433
 
Selection GuideProduct CatalogueInstruction Manual
 
2433

Frequency Selector Switch to eliminate the effect of harmonics.
Three AC current ranges:40mA/400mA/400A.

MODEL2433R
 
Selection GuideInstruction Manual
 
2433R

Frequency Selector Switch to eliminate the effect of harmonics.
Three AC current ranges:40mA/400mA/400A.

MODEL2434
 
Selection GuideProduct CatalogueInstruction Manual
 
2434

Least affected by external stray magnetic field.
20mA AC max. in proximity to a 15mm-dia conductor carrying 100A AC
Frequency Selector Switch to eliminate the effect of harmonics.