Jumat, 19 Februari 2016

Kyoritsu KEW 1051/1052 Digital Multimeter

Digital Multimeter

KEW1051/1052
 
Selection GuideProduct CatalogueInstruction Manual
Software (* 1052 only)
 

High Accuracy, High Performance and Reliable Measurements
0.09% basic DC accuracy
Large display with 6,000 counts
True-RMS Measurements
True-RMS or MEAN value detection mode can be selected *
Low-pass filter for motor drive measurements
User calibration function
Safety design for industrial use
Complies with IEC 61010-1 CAT IV 600V,
CAT III 1000V
Terminal shutter to prevent incorrect test leads' insertion in current terminals
Very wide operating temperature range from
-10 to 55ºC

1051/1052
CE
(Photo: 1052)
Reliable support for data management *
Large data internal memory *
KEW 1052: 1,600 data (logging), 100 data (manual)
Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set) *
* Only for KEW 1052
* MAX 32,767 data can be transferred.

TRUE RMSCAT IV 600V
 
KEW 1051KEW 1052
Detection modeRMSMEAN/RMS (switch)
DC V600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ [600mV/60/600/1000V], 11MΩ [6V])

|±0.09%rdg±2dgt (Basic accuracy)
AC V [RMS]600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ<200pF [600mV], 11MΩ<50pF [6V],
10MΩ<50pF [60/600/1000V])


|±0.5%rdg±5dgt (Basic accuracy)
DC A600.0/6000µA/60.00/440.0mA/6.000/10.00A

|±0.2%rdg±2dgt (Basic accuracy)
AC A [RMS]600.0/6000µA/60.00/440.0mA/6.000/10.00A

|±0.75%rdg±5dgt (Basic accuracy)
Ω600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ

|±0.4%rdg±1dgt (Basic accuracy)
Continuity buzzer600.0Ω (The buzzer turns on for resistances lower than 50±30Ω)
Diode test2.000V|±1%rdg±2dgt
Open curcuit voltage: <3.5V (Approx. 0.5mA Measuring Current)
Capacitance10.00/100.0nF/1.000/10.00/100.0/1000µF

|±2%rdg±5dgt (Basic accuracy)
Frequency10.00 - 99.99/90.0 - 999.9Hz/0.900 - 9.999/9.00 - 99.99kHz

|±0.02%rdg±1dgt (Basic accuracy)
Temperature-50 - 600ºC|±2%rdg±2ºC (with the use of K-type Temperature probe)
Other functionsData Hold (D/H), Auto Hold (A/H), Range Hold (R/H),
Maximum value (MAX) *, Minimum value (MIN) *, Average value (AVG) *, Zero Adjustment (Capacitor, Resistance), Save to Memory *,
LCD backlight
Withstand voltage6,880V/5 sec.
Applicable
standards
IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2,
IEC 61010-031, IEC 61326-1 (EMC)
Power sourceR6 (1.5V)×4 (Auto power off: approx. 20 minutes)
Dimensions192(L)×90(W)×49(D) mm
WeightApprox. 560g (including batteries)
Accessories7220A (Test leads), R6×4, Instruction manual,
8926 (Fuse [440mA/1000V])×1 (included)
8927 (Fuse [10A/1000V])×1 (included)
* Only for KEW 1052

Option

DescriptionModelSpecification
Crocodile clip test lead7234CAT IV 600V, CAT III 1000V
AC/DC Clamp Sensor8115AC 130A/DC 180A
USB Communication set8241USB adaptor + USB cable + DMM Software
DMM Printer full set82498243 + 8246 + 8248
Printer Communication set8243Printer Adapter + RS232 cable
Printer8246Printer + Thermal paper (1 roll)
AC adapter for printer [EU]8248AC230V±10%
Thermal paper for printer824710 rolls
Temperature probes8405Max. 500ºC
(Surface type, Point material: Ceramic)
8406Max. 500ºC (Surface type)
8407Max. 700ºC (Liquid, Semi-solid)
8408Max. 600ºC (Air, Gas)
Carrying case9154for the main unit with testi leads and communication cable