Senin, 22 Februari 2016

KYORITSU Leakage Clamp Meters MODEL 2432

Leakage Clamp Meters

MODEL2432
Selection GuideProduct CatalogueInstruction Manual

High Sensitive Model
Frequency Selector Switch to eliminate the effect of harmonics.
Three AC current ranges : 4mA/40mA/100A

Ø40ØMAXAC100AResolution 0.001mAFilter
PEAK 10ms
2432
CE
AC A
(50/60Hz)
4/40mA/100A
|±1%rdg±5dgt (4/40mA)
|±1%rdg±5dgt (0 - 80A)
|±5%rdg (80.1 - 100A)
AC A
(WIDE)
4/40mA/100A
|±1%rdg±5dgt [50/60Hz],
|±2.5%rdg±10dgt [20Hz - 1kHz] (4/40mA)
|±1%rdg±5dgt [50/60Hz],
|±2.5%rdg±10dgt [40Hz - 1kHz] (0 - 80A)
|±5%rdg [50/60Hz],
|±10%rdg [40Hz - 1kHz] (80.1 - 100A)
Frequency Response20Hz - 1kHz (40Hz - 1kHz:100A)
Maximum
Circuit Voltage
600V AC/DC (between line/neutral)
300V AC/DC (against earth)
Conductor SizeØ40mm max.
Safety StandardIEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-032
Effect of External
Stray Magnetic Field
2mA AC approx. in proximity to a 15mm-dia
conductor carrying 100A AC
Withstand Voltage3700V AC for 1 minute
Response TimeApprox. 2 seconds
Power SourceTwo R03 or equivalent (DC1.5V) batteries
Dimensions185(L) × 81(W) × 32(D)mm
Weight290g approx.
Accessories9052 (Carrying Case)
R03 (1.5V) × 2
Instruction Manual
Optional8008 (Multi-Tran)*

Tidak ada komentar:

Posting Komentar