DC A |
20/100mA (Auto ranging) |
|
| ±0.2%rdg±5dgt | (0.00mA - 21.49mA) |
| ±1.0%rdg±5dgt | (21.0mA - 120.0mA) |
|
Conductor size | Ø6mm max. |
Analog output | Recorder: DC 1000mV against DC 100mA |
Withstand voltage | 2210V AC for 5 seconds |
Applicable standards | IEC 61010-1, 61010-2-030 CAT II 300V IEC 61010-2-032 IEC 61326-1, 61326-2-2 IEC 60529 IP40 |
Operating temperature & humidity | -10 - +50ºC < 85% |
Storage temperature & humidity | -20 - +60ºC < 85% |
Power source | R6/LR6 (AA) (1.5V) × 4 |
Dimensions | 111(L) × 61(W) × 40(D)mm : Display unit 104(L) × 34(W) × 20(D)mm : Sensor 700mm : Sensor cable |
Weight | Approx. 290g (including batteries) |
Accessories | 9096 (Carrying case), LR6 (AA) × 4, Instruction Manual |
Optional | 7256 (Output cord)
|
Tidak ada komentar: