 |  | AC A (RMS) |  |  |
 |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Range |  |  |  | 30.00 / 300.0 / 3000A |  |  |
 |  |  |  |  |  |  |
 |  |  |
 |  |  |  |  |  |  |
 |  |  |  | Accuracy |  |  |  | ±3%rdg±5dgt (45 - 500Hz) (At the center of the circle formed by the flexible sensor) |  |  |
 |  |  |  |  |  |  |
 |
 |  |  |  |  |
 |  | Conductor size |  |  |  | Φ150mm max. |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Influence of Conductor position |  |  |  | Additional ±3% (max.) depending on the distance from the center position |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Overload protection |  |  |  | 5000A AC for 10 seconds |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Applicable standards |  |  |  | IEC 61010-1, IEC 61010-2-030 CAT III 1000V / CAT IV 600V Pollution degree 2 IEC 61010-2-032, IEC 61326-1 (EMC), IEC 60529 IP40 |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Operating temperature & humidity |  |  |  | 0 - +50ºC, less than 80% RH (without condensation) |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Storage temperature & humidity |  |  |  | -10 - +60ºC, less than 70% RH (without condensation) |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Power source |  |  |  |
R03 / LR03 (AAA) (1.5V) × 2 |
* | Continuous measuring time: approx. 120hours (Auto power off: approx. 15 minutes) |
|  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Dimension |  |  |  | 120 (L) × 70 (W) × 26 (H) mm : Display unit 1.8m : Sensor cable |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Weight |  |  |  | Approx. 300g (including batteries) |  |  |
 |  |  |  |  |
 |
 |  |  |  |  |
 |  | Accessories |  |  |  | 9174 (Carrying case), LR03 (AAA) × 2, Instruction manual |  |  |
 |  |  |  |  |

|
Tidak ada komentar: