KYORITSU AC/DC Digital Clamp Meters MODEL 2010

AC/DC Digital Clamp Meters

MODEL2010
 
Selection GuideInstruction Manual
 

High sensitivity, miniature AC/DC clamp meter.
0.1mA minimum resolution for AC current and 1mA minimum resolution for DC current.
Output terminal for recorder connection.

Ø7.5MAX AC/DC20AOUT PUT 
External Power Supply  
2010
Never make current measurement on a circuit above 60V AC/DC
as the instrument is designed for use on low voltage circuits only.
 
AC A200mA/2/20A
|±1%rdg±2dgt [50/60Hz] (200mA)
|±1.5%rdg±4dgt [40Hz - 2kHz] (200mA)
|±1%rdg±2dgt [50/60Hz] (2A)
|±2.5%rdg±5dgt [40Hz - 2kHz] (2/20A)
DC A2/20A
|±1%rdg±2dgt (2A)
|±1.5%rdg±4dgt (20A)
Output
Recorder :DC200mV against AC200mA/2/20A
 DC200mV against DC2/20A
Conductor SizeØ7.5mm max.
Frequency ResponseDC, 40Hz - 2kHz
Withstand Voltage750V AC for 1 minute
Power Source6LF22(9V) × 1 or AC Adaptor
Dimensions142(L) × 64(W) × 26(D)mm
153(L) × 23(W) × 18(D)mm
Clamp Sensor
Weight220g approx.
Accessories9071 (Carrying Case)
Alkaline 6LF22 × 1
Instruction Manual
Optional8022 (AC Adaptor) (110V) 
8023
 (AC Adaptor) (220V)
7256 (Output cord)