Senin, 22 Februari 2016

KYORITSU Leakage Clamp Meters MODEL 2433R

Leakage Clamp Meters

MODEL2433R
 
Selection GuideInstruction Manual
 

Frequency Selector Switch to eliminate the effect of harmonics.
Three AC current ranges:
40mA/400mA/400A.

TRUE RMS
Ø40MAX AC400AResolution 0.01mAFilter
PEAK 10ms   
2433R
CE
 
AC A
(50/60Hz)
40/400mA/400A
|±1%rdg±5dgt (40/400mA)
|±1%rdg±5dgt (0 - 300A)
|±2%rdg (300.1 - 399.9A)
AC A
(WIDE)
40/400mA/400A
|±1%rdg±5dgt [50/60Hz],
|±2.5%rdg±10dgt [20Hz - 1kHz] (40/400mA)
|±1%rdg±5dgt [50/60Hz],
|±2.5%rdg±10dgt [40Hz - 1kHz] (0 - 300A)
|±2%rdg [50/60Hz],
|±5%rdg [40Hz - 1kHz] (300.1 - 399.9A)
Frequency Response20Hz - 1kHz [40Hz - 1kHz:400A]
Maximum
Circuit Voltage
600V AC/DC (between line/neutral)
300V AC/DC (against earth)
Conductor SizeØ40mm max.
Safety StandardIEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-032
Effect of External
Stray Magnetic Field
10mA AC approx. in proximity to a 15mm-dia
conductor carrying 100A AC
Withstand Voltage3700V AC for 1 minute
Response TimeApprox. 2 seconds
Power SourceTwo R03 or equivalent (DC1.5V) batteries
Dimensions185(L) × 81(W) × 32(D)mm
Weight270g approx.
Accessories9052 (Carrying Case) R03 (1.5V) × 2
Instruction Manual
Optional8008 (Multi-Tran)*