KYORITSU Flexible Clamp Sensor KEW 8130

Flexible Clamp Sensor

KEW8130
 
Applicable model listApplicable model list
 

Can measure AC current up to 1000A
Flexible and light weight by the air core coil used at the sensor part
Designed to meet the international safety standard
IEC 61010-1 CAT IV 300V, CAT III 600V


Applicable model
5010/5020 (*)6300630563106315
8130
CE

*When you use the sensors with KEW 5010/5020, please check the "Applicable model list" to check if your KEW 5010/5020 can be used with the sensors.

Φ110MAX AC 1000A
Conductor sizemax. Φ110mm
Rated currentAC 1000A
Output voltageAC 500mV / 1000A (AC 0.5mV/A)
Accuracy±0.8%rdg±0.2mV (45Hz - 65Hz)
±1.5%rdg±0.4mV (40Hz - 1kHz)
Phase shiftwithin ±2.0° (45Hz - 65Hz)
Cable lengthApprox. 3m
Output connectorMINI DIN 6PIN
Operating temperature & humidity ranges-10 - 50°C, relative humidity 85% or less (no condensation)
Output impedance100Ω or less
Applicable standardsIEC 61010-1, IEC 61010-2-030,
IEC 61010-2-032 CAT IV 300V / CAT III 600V Pollution degree 2,
IEC 61326
WeightApprox. 180g
AccessoriesInstruction manual, Cable marker,
9095 (Carrying case)