Photo | Type | Description | Measuring input/Process connection | Documents |
---|
LF9648
|
Conductivity Meter
4-digit, 14.2 mm red,
Measuring range programmable,
Temperature compensation via Pt100/Pt1000,
max. 4 alarm outputs,
Supply voltage:
24 V DC, 24 V AC, 115 V AC, 230 V AC,
Panelmeter DIN 96x48mm
|
Direct connection of 2- or 4- electrode cells,
0..2000 mS/cm |
LF1010
|
Conductivity Meter
4-digit, 14.2 mm red,
Measuring range programmable,
Temperature compensation via Pt100/Pt1000,
max. 2 alarm outputs,
Supply voltage:
24 V DC, 24 V AC, 115 V AC, 230 V AC,
Field mounting
|
Direct connection of 2- or 4- electrode cells,
0..2000 mS/cm |
UNICON-LF
|
Conductivity-Converter
Measuring range programmable,
Temperature compensation via Pt100/Pt1000,
Output 4..20 mA for
conductivity and temperature,
max. 2 alarm outputs,
Supply voltage: 14..30 V DC,
Loop powered,
Field- or head mounting
|
Direct connection of 2- or 4- electrode cells,
0..2000 mS/cm |
GLMU
|
Conductivity Transmitter incl. Cell
Temperature compensation,
Output 0..1/10 V (3-wire)
4..20 mA (2-wire),
LC-Display 4 digit,
Supply voltage:
12..30 V DC at 4..20 mA
18..30 V DC at 0..10 V
|
Direct connection of 2- or 4-electrode cells via plug
200 µS/cm..500 mS/cm
|
Conductivity Cells
LF2203
|
2-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PVC-U DIN 8061/8062, Graphite (electrodes)
|
For flow fitting DFA25
Pipe diameter 25..63 mm,
Measuring range:
100 µS/cm..2 mS/cm
|
LF2603
|
2-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PVC-U DIN 8061/8062,
SS-type (electrodes)
|
Process thread G1/2A, G3/4A, R1/2, G3/4,
Measuring range:
20 µS/cm..100 µS/cm
|
LF2613
|
2-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PVC-U DIN 8061/8062,
Electrodes (Graphite)
|
Process thread G1/2A, G3/4A, R1/2, G3/4
Measuring range:
100 µS/cm..2 mS/cm
|
LF2653HT
|
2-Electrode High Temperature
Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Temperature range 0..200 °C,
Process material SS-type 1.4404, ceramic
|
Process thread G3/4A, G1A, G1 1/4A
Measuring range:
0.5 µS/cm..50 µS/cm
|
LF1453/LF2453
|
2-Electrode Ultra-pure water
Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material SS-type, PVDF,
Field or head mounting
|
Clamp-connection acc. to DIN 32676 or Südmo-Aseptik
Measuring range:
0.5 µS/cm..50 µS/cm
|
LF1553/LF2553
|
2-Electrode Ultra-purewater
Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material SS-type 1.4404, PEEK,
Field or headmounting
|
VARIVENT Inline-case
Measuring range:
0.5 µS/cm..50 µS/cm
|
LF1653/LF2653
|
2-Electrode Ultrapure water
Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material SS-type 1.4404 electropolished, PVDF,
Field or headmounting
|
Process thread G3/4A, G1A
Measuring range:
0.5 µS/cm..50 µS/cm
|
LF4003
|
4-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PVC-U, casting resin, SS-type 1.4305, Graphite (electrodes), PUR cable
|
Immersion Cell up to 100 m depth of water
Measuring range:
20 µS/cm..500 mS/cm
|
LF3043/LF4043
|
4-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PA, casting resin, Graphite (electrodes)
Field- or head mounting
|
Immersion-cell for ducts, basins and open systems
Measuring range:
20 µS/cm..500 mS/cm
|
LF3213/LF4213
|
4-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PVC-U, casting resin, Graphite (electrodes)
Field- or head mounting
|
For Flow fitting DFA32
and pipe diameter 20..63 mm
Measuring range:
20 µS/cm..500 mS/cm
|
LF3433/LF4433
|
4-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PEEK, PVDF, SS-type 1.4404, Graphite (electrodes)
Field- or head mounting
|
Clamp-connection acc.. to DIN 32676
Measuring range:
20 µS/cm..500 mS/cm
|
LF3533/LF4533
|
4-Electrode Hygienic
Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PEEK, SS-type 1.4404, Graphite (electrodes)
Field- or headmounting
|
VARIVENT Inline-case
Measuring range:
20 µS/cm..500 mS/cm
|
LF3623/LF4623
|
4-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PVDF, casting resin, Graphite (electrodes)
Field- or headmounting
|
Process thread G3/4A, G1A acc. to DIN ISO 228
Measuring range:
20 µS/cm..500 mS/cm
|
LF3733/LF4733
|
4-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PEEK, PVDF, SS-type 1.4404, casting resin, Graphite (electrodes),
Field- or headmounting
|
Milk pipe connection acc. to DIN 11887,
Measuring range: |